MicroPette Single Channel Adjustable Manual Pipette

MicroPette
Pipettes are suitable for precise sampling and transfer of liquids. Using the principle of air displacement, the liquid is transferred using a removable disposable nozzle. The pipette is composed of a positioning part, a volume adjustment indicating part, an ejector device, a piston sleeve and a suction nozzle.

FEATURES

•   Pipettes cover a volume range from 0.1μL to 10mL

•   Ergonomic design provides excellent operating experience

•   Large display window allows for easy volume identification

•   Easy calibration and maintenance

•   Each MicroPette supplied with an individual calibration certificate according to ISO8655

SPECIFICATIONS


Single-channel Adjustable Volume Pipettes

Cat. No.

Volume Range

Increment

Test Volume

Accuracy error

Precision error





%

μl

%

μl

7030201001

0.1-2.5μl

0.05μl

2.5μl

2.50%

0.0625

2.00%

0.05

1.25μl

3.00%

0.0375

3.00%

0.0375

0.25μl

12.00%

0.03

6.00%

0.015

7030201004

0.5-10μl

0.1μl

10μl

1.00%

0.1

0.80%

0.08

5μl

1.50%

0.075

1.50%

0.075

1μl

2.50%

0.025

1.50%

0.015

7030201005

2-20μl

0.5μl

20μl

0.90%

0.18

0.40%

0.08

10μl

1.20%

0.12

1.00%

0.1

2μl

3.00%

0.06

2.00%

0.04

7030201006

5-50μl

0.5μl

50μl

0.60%

0.3

0.30%

0.15

25μl

0.90%

0.225

0.60%

0.15

5μl

2.00%

0.1

2.00%

0.1

7030201008

10-100μl

1μl

100μl

0.80%

0.8

0.15%

0.15

50μl

1.00%

0.5

0.40%

0.2

10μl

3.00%

0.3

1.50%

0.15

7030201009

20-200μl

1μl

200μl

0.60%

1.2

0.15%

0.3

100μl

0.80%

0.8

0.30%

0.3

20μl

3.00%

0.6

1.00%

0.2

7030201011

50-200μl

1μl

200μl

0.60%

1.2

0.15%

0.3

100μl

0.80%

0.8

0.30%

0.3

50μl

1.00%

0.5

0.40%

0.2

7030201014

100-1000μl

5μl

1000μl

0.60%

6

0.20%

2

500μl

0.70%

3.5

0.25%

1.25

100μl

2.00%

2

0.70%

0.7

7030201016

200-1000μl

5μl

1000μl

0.60%

6

0.20%

2

500μl

0.70%

3.5

0.25%

1.25

200μl

0.90%

1.8

0.30%

0.6

7030201017

1000-5000μl

50μl

5000μl

0.50%

25

0.15%

7.5

2500μl

0.60%

15

0.30%

7.5

1000μl

0.70%

7

0.30%

3

7030201033

2-10ml

0.1ml

10ml

0.60%

60

0.20%

20

5ml

1.20%

60

0.30%

15

2ml

3.00%

60

0.60%

12



Fixed Volume Pipettes

Cat. No.

Volume Range

Increment

Test Volume

Accuracy error

Precision error





%

μl

%

μl

7030202018

5μl

-

5μl

1.30%

0.065

1.20%

0.06

7030202019

10μl

-

10μl

0.80%

0.08

0.80%

0.08

7030202020

20μl

-

20μl

0.60%

0.12

0.50%

0.1

7030202021

25μl

-

25μl

0.50%

0.125

0.30%

0.075

7030202022

50μl

-

50μl

0.50%

0.25

0.30%

0.15

7030202023

100μl

-

100μl

0.50%

0.5

0.30%

0.3

7030202024

200μl

-

200μl

0.40%

0.8

0.20%

0.4

7030202025

250μl

--

250μl

0.40%

1

0.20%

0.5

7030202026

500μl

-

500μl

0.30%

1.5

0.20%

1

7030202027

1000μl

-

1000μl

0.30%

3

0.20%

2

7030202028

2000μl

-

2000μl

0.30%

6

0.15%

3

7030202029

5000μl

-

5000μl

0.30%

15

0.15%

7.5

REQUEST A QUOTE